Low temperature constant temperature circulator

Common Issues and Solutions for Water Circulation Systems: 1. The water circulation system has been in use for over a year, and the cooling performance seems to be gradually decreasing. This issue becomes more noticeable when the ambient temperature is high. A: While water recycling is a straightforward process, regular maintenance is essential. Many problems that appear to be faults are actually caused by neglecting routine upkeep. The water circulation system needs to remove both its own power consumption and the heat from the load via the refrigerant, which is then dissipated through the radiator located at the front of the unit. If the area in front of the radiator gets clogged with dust or fibers, it will significantly reduce the cooling efficiency. In normal conditions, a drop in cooling capacity is usually due to poor airflow or excessively high ambient temperatures. 2. The water circulation system worked fine before, but now it's much noisier than usual. What could be the cause? A: As mentioned earlier, daily maintenance plays a key role in this problem. Although distilled water is used, it's nearly impossible to avoid small impurities. Most systems are set to operate around 20°C, which is an ideal environment for microbial growth. Over time, these microorganisms can accumulate in the water lines, blocking the filters and causing poor water return. This can lead to increased noise from the pump. Additionally, they may attach to the surface of the heat exchanger, reducing heat transfer efficiency and lowering the overall cooling capacity. To prevent this, it's important to follow the maintenance guidelines in the manual—regularly clean the internal tank and ensure it's kept dry if the system is not in use for extended periods. 3. I think there might be a leak in the water circulation system. Sometimes there are a few drops on the floor. Is there a leak in the waterway? A: In most cases, there is no actual leakage in the waterway during normal operation. However, if the humidity in the surrounding air is high, condensation may form on the water pump, pipe joints, or external pipes of the system. When this condensation builds up, it can drip onto the floor, giving the impression of a leak. There’s no need to worry about water escaping from the internal waterway. If you're concerned, you can turn on the air conditioner to lower the room temperature or use a dehumidifier to prevent condensation from forming.

Dog Grooming Scissors

Dog Grooming Scissors,Dog Hair Scissors,Dog Grooming Curved Scissors,Pet Hair Cutting Scissors

Suzhou Chuangfan Trade Co.,ltd , https://www.r4petz.com